Device | Photo | Mfg. country | Size, mm | Weight, g | Power supply | Display | Sound | Vibration | Detector type | Range, μSv/h | Range, μR/h | Measurement time, seconds | Measuring of beta and gamma radiation and range of energy | PC link | Extra features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Radmetron PM1211[1] | ![]() |
128x48x20 | 130 | 1 CR2450 | LCD | Yes | No | Geiger–Müller tube | 0.01 – 10e4 | 1.14 – 11.4e6 | yes (48 keV – 3 MeV) | USB | |||
Radmetron PM1300[2] | ![]() |
85x57x21 | 95 | AAA | LCD | Yes | Yes | Silicon PIN diode | 0.01 – 10e6 | 1.14 – 11.4e5 | 0 – 20 | X-ray and Gamma (15 keV – 20 MeV) | USB, RF-interface | GPS | |
Radmetron PM1300GN[3] | ![]() |
130х57х35 | 200 | built-in rechargeable, or optional AAA | LCD | Yes | Yes | Silicon PIN diode, scintillator, silicon photomultiplier | 0.01 – 10e3 | 1.14 – 11.4e7 | 0 – 20 | Yes (0.025 eV – 15 MeV for neutron radiation, 15 keV – 20 MeV for photon radiation) | USB, RF-interface | ||
Radmetron PM1401GNM[4][a] | ![]() |
195х57х32 | 450 | 1 АА | LCD | Yes | Yes | 3He, Geiger–Müller tube, CsI(Tl) scintillator | 0.1 – 9999 ±20% | 0.25 | Yes (0.033 – 3 MeV for gamma, 0.025 eV– 14 MeV for neutron) | USB | |||
Radmetron PM1401MA[5] | ![]() |
110×62×38 | 320 | 1 АА | LCD | Yes | Yes | CsI(Tl) scintillator | 0.05 – 40 ±20% | 0.25 | Yes (0.05 – 3 MeV) | USB | |||
Radmetron PM1401K-3[6] | ![]() |
262x60x65 | 820 | 2 АА | Color LCD | Yes | Yes | 3He, Geiger–Müller tube, CsI(Tl) scintillator | 0.1 μSv/h – 100 mSv/h | Yes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation) | USB | GPS | |||
Radmetron PM1401K-3M[6] | ![]() |
262x60x65 | 820 | 2 АА | Color LCD | Yes | Yes | Geiger–Müller tube, CsI(Tl) scintillator | 0.1 μSv/h – 100 mSv/h | Yes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation) | USB | GPS | |||
Radmetron PM1405P[7][b] | ![]() |
136×69×38 | 340 | 1 АА | Yes | No | Geiger–Müller tube | 0.1 – 3e5 ±20% | 11.4 – 34.2e6 ±20% | Yes (50 keV – 3 MeV) | USB | ||||
Radmetron PM1603A[8] | ![]() |
50х56х19 | 85 | 1 CR2032 | LCD with backlight | Yes | No | Geiger–Müller tube | 0.01 – 10e3 | 1.14 – 11.4e2 | Yes (48 keV – 3 MeV) | IR adapter | alarm clock, timer, stopwatch, calendar | ||
Radmetron PM1603B[9] | Yes | No | Yes (48 keV – 3 MeV) | ||||||||||||
Radmetron PM1611[10] | ![]() |
60×65×22 | ≤70 | built-in rechargeable | LCD | Yes | Yes | Geiger–Müller tube | 0.1 – 10e6 ±15% | 11.4 – 11.4e8 ±15% | 0 – 2 | Yes (20 keV – 10 MeV) | USB | ||
Radmetron PM1611B[10] | ![]() |
60×65×25 | ≤80 | AAA | LCD | Yes | Yes | Geiger–Müller tube | 0.1 – 10e6 ±15% | 11.4 – 11.4e8 ±15% | 0 – 2 | Yes (20 keV – 10 MeV) | USB | ||
Radmetron PM1621[11] | ![]() |
87х72х39 | 150 | 1 АА | LCD | Yes | No | Geiger–Müller tube | 0.1 – 10e4 ±15% | 11.4 – 11.4e6 ±15% | Yes (10 KeV – 20 MeV) | IR adapter | |||
Radmetron PM1621A[12] | ![]() |
87х72х39 | 165 | 1 АА | LCD | Yes | No | Geiger–Müller tube | 0.1 – 10e5 ±15% | 11.4 – 11.4e7 ±15% | Yes (10 KeV – 20 MeV) | IR adapter | |||
Radmetron PM1621M[13] | ![]() |
87х72х39 | 185 | 1 АА | LCD | Yes | No | Geiger–Müller tube | 0.01 – 10e4
±15% |
11.4 – 11.4e6 ±15% | Yes (10 keV – 20 MeV) | IR adapter | |||
Radmetron PM1621MA[14] | ![]() |
87х72х39 | 185 | 1 АА | LCD | Yes | Yes | Geiger–Müller tube | 0.01 – 10e5
±15% |
11.4 – 11.4e7 ±15% | Yes (10 KeV – 20 MeV) | IR adapter | |||
Ludlum Model 23[15] | ![]() |
112.8x30x12 | 55.9 | CR2450 | OLED | Yes | No | MOSFET | 1 – 99.1e4 ≤±10% | 114 – 11.4e7 ≤±10% | X-ray and Gamma | IR reader | |||
Ludlum Model 23-1[16] | ![]() |
112.8x30x12 | 55.9 | CR2450 | OLED | Yes | No | MOSFET | 1 – 99.9e3 ≤±10% | 114 – 11.47 ≤±10% | Gamma and X-ray | IR reader | |||
Ludlum Model K8[17] | ![]() |
39x25x13 | 13 | CR2032 | LED | Yes | No | MOSFET | 0.01 – 99.9e7 | gamma | No | ||||
Ludlum Model 25[18][19][20] | ![]() |
76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 0.1 – 87.6e5 | 10 – 99.9e7 | Yes (60 keV – 2 MeV) | ||||
Ludlum Model 25-1[18][19][20] | ![]() |
76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 1 – 99.9e5 | 114 – 11.4e8 | Yes (60 keV — 2 MeV) | ||||
Ludlum Model 25-IS[18][19][21] | ![]() |
76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 0.09 —87.6e5 | 10 —99.9e7 | Yes (60 keV — 2 MeV) | ||||
Ludlum Model 25-IS-1[18][19][21] | ![]() |
76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 1 — 99.9e5 | 114 — 11.4e8 | Yes (60 keV — 2 MeV) | ||||
FNISRI GC-01[22] | ![]() |
120x78x27 | 1100mAh Lithium-ion battery | LCD with backlight | Yes | Yes | Geiger–Müller tube | 0.01 — 50e3 | 1 — 50e5 | combined, 48 keV - 1.5 Mev ≤ ±30% | Hydrogen Cyanide Detector | ||||
FNISRI GC-02[23] | ![]() |
850 mAh Lithium-ion battery | LCD with backlight | Yes | Geiger–Müller tube | Yes | |||||||||
Radiascan 501[24][25] | ![]() |
110х60х23 | 110 | 2 AAA battery | Color OLED display | Yes | No | Geiger–Müller tube Beta 1-1 | 0.01—10e3 | 1—10e5 | 1 — 60 | No | Yes | food contamination tester, "background pattern analysis algorithm"[c] | |
SA-05A[26] | ![]() |
![]() |
119x65x26.5 | 135 | Built-in lithium polymer battery | LCD | No | No | Geiger–Müller tube LND 713 | 0.01–6000 | No | 1 – 60 | 0.05–1.3 MeV | USB | Clock, calendar and data logger |
Radiascan 701[24] | ![]() |
110х60х23 | 110 | 2 AAA battery | Color OLED display | Yes | No | Geiger–Müller tube Beta 1-1 | 0.01—10e3 | 1—10e5 | 1 — 60 | Combined | USB | food contamination tester | |
ANRI 01-02 Sosna[27][24] | ![]() |
![]() |
133x82x45 | 350 | Nine-volt battery | LCD | Yes | No | Two to four Geiger–Müller tubes | 0.1–100 | 10–10e4 | 20±5 | Combined, 0.5–3.0 MeV | No | |
bGeigie Nano[28][29] | ![]() |
![]() |
149x103x54 | 440 | Li-Po | LCD | No | Yes | one Geiger–Müller tube | 0–1000 | 0–100 | 1 – 60 | Yes | USB, Bluetooth, and WiFi | Waterproof,Clock GPS, open-source |
bGeigieZen Standard[28][30] | ![]() |
![]() |
165x98x52 | 450 | replaceable 18650 3000mA
+ USB-C +QI wireless |
IPS LCD with touchscreen | No and yes (app can produce sound) | No | one LND7317 Geiger–Müller tube | 0-1000 | 0-100 | 1 — 60 | ![]() |
USB, Bluetooth, and WiFi | Waterproof,Clock GPS, open-source.
WiFi and BLE upload of data. |
bGeigieZen NFW[30] | ![]() |
![]() |
165x98x52 | 450 | replaceable 18650 3000mA
+ USB-C +QI wireless |
IPS LCD with touchscreen | No and yes (app can produce sound) | No | one LND7317 Geiger–Müller tube | 0-1000 | 0-100 | 1 — 60 | ![]() |
USB, Bluetooth, and WiFi | Waterproof,Clock GPS, open-source.
WiFi and BLE upload of data. |
DKG-RM1203M[31] | ![]() |
125x42x24 | 90 | Two LR44 | LCD | Yes | No | Geiger–Müller tube | 0.01–2000 | 1–2*10e5 | No | Infrared | Clock with alarm | ||
DKR-04 | 74х48х16 | 50 | AAA | LCD | Yes | No | Semiconductor | 0.1–10e6 | 10–10e8 | 4 — 256 | No | No | |||
Ecotest DKG-21M[32] | ![]() |
98×58×18 | 140 | CR2450 Button cell | Yes | Geiger–Müller tube | 0.1 – 10e5
±15% |
Yes (0.05 – 6 MeV) | infrared | ||||||
Ecotest DKG-24 "PRD Guarder"[33] | ![]() |
60×110×30 | 250 | 2 АА | backlit monochrome display | Yes | Yes | CsI(Tl) scintillator, silicon semiconductor | 0.01 – 107 | 10 – 90 | Yes (0.02 – 10.0 MeV) | Bluetooth, USB | gyroscope, GPS | ||
Ecotest MKS-03D "Swift" | ![]() |
![]() |
111x73x28 | 200 | 2 АА | LCD with backlight | Yes | Yes | Geiger–Müller tube | 0.1—105 | 10—107 | 4 — 128 | Combined, 0.12—3.0 MeV Beta measurement range 5—105 min−1 cm−2 | USB | Clock with alarm, optional case |
Ecotest MKS-05 "Terra-P" | ![]() |
![]() |
120×52×26 | 150 | Two AAA | LCD | Yes | No | Geiger–Müller tube | 0.1–1000 | 10–10e5 | 5 — 70 | Combined, 0.5–3.0 MeV | No | Clock with alarm, cover as option |
Ecotest MKS-05 "Terra" (New edition) | ![]() |
120×52×26 | 150 | Two AAA | LCD with backlight | Yes | Yes | Geiger–Müller tube | 0.1–10e4 | 10–10e6 | 1 — 70 | Combined, 0.5–3.0 MeV | Bluetooth | Clock with alarm, cover | |
Ecotest MKS-05 "Terra" (with Bluetooth channel)[34] | ![]() |
120×52×26 | 150 | Two AAA | LCD with backlight | ||||||||||
Ecotest MKS-UM | ![]() |
166×70×132 (control unit), 47×95×173 (probe) | 70 (control unit), 30 (probe) | Yes | Geiger–Müller tube | 1 – 10e6 | Yes (0.05 – 3 MeV) | ||||||||
Ecotest RKS-01 "STORA-TU" | ![]() |
160×75×36 | 50 | Two AAA | Yes | 4 Geiger–Müller tubes | 0.1 – 999.9 | Bluetooth | |||||||
GQ GMC-300E +V4[36] | ![]() |
![]() |
AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 328 | 32.8 | 1 — 60 | Combined | USB | |||
GQ GMC-320 +V4[36] | ![]() |
AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 328 | 32.8 | 1 – 60 | Combined | USB | gyroscope, temperature sensor | |||
GQ GMC-320 +V5[36] | ![]() |
AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 328 | 32.8 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope, temperature sensor | |||
GQ GMC-300S[36] | ![]() |
![]() |
AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 1000 | 100 | 1 – 60 | Combined | USB | |||
GQ GMC-320S[36] | ![]() |
AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 1000 | 100 | 1 – 60 | Combined | USB | gyroscope, temperature sensor | |||
GQ GMC-SE[36] | ![]() |
AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 2000 | 200 | 1 – 60 | Combined | USB | ||||
GQ GMC-500[36] | ![]() |
18650 | LCD with backlight | Yes | No | One Geiger–Müller tube | 5000 | 500 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | |||
GQ GMC-500+[36] | ![]() |
![]() |
135x78x25 | 18650 | LCD with backlight | Yes | No | Two Geiger–Müller tubes | 0 – 42.5e3 | 0 – 4.25e6 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | |
GQ GMC-800[36] | ![]() |
AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 2000 | 200 | 1 – 60 | Combined | USB | ||||
GQ GMC-600[36] | ![]() |
18650 | LCD with backlight | Yes | No | SBT-11 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | |||
GQ GMC-600+[36] | ![]() |
18650 | LCD with backlight | Yes | No | LND 7317 | 10e3 | 1000 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | |||
GQ GMC-510[36] | ![]() |
18650 | LCD with backlight | Yes | No | M4011 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | |||
GQ GMC-520[36] | ![]() |
18650 | LCD with backlight | Yes | No | M4011 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | |||
GQ GMC-520+[36] | ![]() |
18650 | LCD with backlight | Yes | No | M4011 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | |||
Radex RD1503, RD1503+[25][24] | ![]() |
![]() |
105х60х26 | 90 | One or two AAA | LCD with backlight | Yes | Only RD1503+ | Geiger–Müller tube | 0.05 – 10 | 5 – 1000 | up to 40 | Combined, 0.1–1,25 MeV | No | |
Radex RD1706[24] | ![]() |
![]() |
105х60х26 | 90 | One or two AAA | LCD with backlight | Yes | Yes | Two Geiger–Müller tubes | 0.05 –1000 | 5 – 10e5 | 1 – 26 | Combined, 0.1–1.25 MeV | No | Background mode |
Radex RD1212[24] | ![]() |
97x68x24 | 80 | One or two AAA | LCD with backlight | Yes | Yes | One Geiger–Müller tube | 0.05 – 999 | 5 – 10e5 | 1 – 10 | Combined, 0.4–3.5 MeV | USB | Background mode, integrated flashlight, time and date functions, multilingual | |
Radex RD1008[24] | ![]() |
![]() |
140х64х26 | 175 | AA | LCD with backlight | Yes | Yes | Two Geiger–Müller tubes | 0.1 – 1000 | 2 – 120 | 2 – 21 | Separated, 0.05–3.5 MeV | No | Background mode, separated indication of beta and gamma radiation |
RadiaCode 102[37][38][39] | ![]() |
![]() |
conflicting answers (124x35x20 or 123x34x18) | 65 | built-in Lithium polymer battery | LCD with backlight | Yes | CsI(Tl) scintillator | 0.01 – 1000 | 1 — 10e5 | 0.5 | yes | USB and Bluetooth | thermometer, clock | |
RadiaCode 103[37][38][40] | ![]() |
conflicting answers (124x35x20 or 123x34x18) | 65 | built-in Lithium polymer battery | LCD with backlight | Yes | CsI(Tl) scintillator | 0.01 – 1000 | 1 — 10e5 | 0.5 | yes | USB and Bluetooth | thermometer, clock | ||
RadiaCode 103G[37][38][41] | ![]() |
conflicting answers (124x35x20 or 123x34x18) | 70 | built-in Lithium polymer battery | LCD with backlight | Yes | GAGG(Ce) Scintillator | 0.01 – 1000 | 1 — 10e5 | 0.5 | yes | USB and Bluetooth | thermometer, clock | ||
RadTarge II D300[42] | ![]() |
69x46x17 | 60 | Built-in lithium ion battery | LCD with backlight | Yes | Yes | YSO scintillator + SiPM | 0.5 – 5000 | 50 – 5e5 | < 8 | No, 0.03–1.5 MeV | USB | Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) | |
RadTarge II D700[43] | ![]() |
69x46x17 | 60 | Built-in lithium-ion battery | LCD with backlight | Yes | Yes | YSO scintillator + SiPM | 0.01 — 1000 | 1 — 10e5 | < 2 | No, 0.02–3 MeV | USB | Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) | |
RadTarge II D900[44] | ![]() |
69x46x17 | 60 | Built-in lithium-ion battery | LCD with backlight | Yes | Yes | YSO scintillator + SiPM | 0.1 – 10e5 | 10 – 10e7 | < 6 | No, 0.02–3 MeV | USB | Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) | |
RKSB-104[24] | ![]() |
154х77х39 | 350 | 1 Nine-volt battery | LCD | No | No | Two Geiger–Müller tubes | 0.1 — 100 | 10 — 2e4 | 18 – 400 | Combined, 0.5–3.0 MeV | No | ||
RKS-107[24] | ![]() |
154x77x39 | 350 | 1 Nine-volt battery | LCD | No | No | Geiger–Müller tube | 0.1 — 99.99 | 10 — 9999 | |||||
Pripyat RKS-20.03[45][25] | ![]() |
![]() |
Two SBM-20 Geiger–Müller tubes | ||||||||||||
DKG-RM1610[24] | ![]() |
58х58х18 | 70 | Built-in accumulator | LCD | Yes | Yes | One Geiger–Müller tube | 0.01 — 1.2e6 | 1 — 1.2e8 | No | USB | Shock protection | ||
EcotestCARD[d] [25][24] | ![]() |
80 | CR2450 | LCD | Yes | No | Semiconductor | 0.1–10e6 | 10–10e8 | Infrared | |||||
SOEKS 01M[25] | ![]() |
![]() |
Geiger–Müller tube |
Notes
[edit]References
[edit]- ^ "Electronic Dosimeter PM1211". Radmetron. Retrieved 2025-05-01.
- ^ "Electronic Personal Dosimeter PM1300". Radmetron. Retrieved 2025-05-01.
- ^ "Electronic Personal Dosimeter PM1300GN". Radmetron. Retrieved 2025-05-02.
- ^ "Personal Radiation Detector PM1401GNM". Radmetron. Retrieved 2025-05-04.
- ^ "Gamma Personal Radiation Detector PM1401MA". Radmetron. Retrieved 2025-05-04.
- ^ a b "Multipurpose Hand-Held Radiation Monitor/Identifier PM1401K-3". Radmetron. Retrieved 2025-05-04.
- ^ "Survey meter PM1405P". Radmetron. Retrieved 2025-05-03.
- ^ "Wrist Gamma Dosimeter РМ1603A". Radmetron. Retrieved 2025-05-01.
- ^ "Wrist Gamma Dosimeter РМ1603B". Radmetron. Retrieved 2025-05-01.
- ^ a b "X-ray and Gamma Radiation Personal Dosimeter РМ1611". Radmetron. Retrieved 2025-05-02.
- ^ "X-ray and Gamma Radiation Personal Dosimeter РМ1621". Radmetron. Retrieved 2025-05-02.
- ^ "X-ray and Gamma Radiation Personal Dosimeter РМ1621A". Radmetron. Retrieved 2025-05-02.
- ^ "X-ray and Gamma Radiation Personal Dosimeter РМ1621M". Radmetron. Retrieved 2025-05-02.
- ^ "X-ray and Gamma Radiation Personal Dosimeter РМ1621MA". Radmetron. Retrieved 2025-05-02.
- ^ "Model 23: mrem Electronic Personal Dosimeter". ludlums.com. Retrieved 2025-04-10.
- ^ "Model 23-1 mSv Electronic Personal Dosimeter - Ludlum Measurements Inc". ludlums.com. Retrieved 2025-04-10.
- ^ "Model K8 NUKE Safeguard Personal Radiation Indicator - Ludlum Measurements Inc". ludlums.com. Retrieved 2025-04-10.
- ^ a b c d "Model 25 Series: Personal Radiation Monitor" (PDF). Ludlum Measurements. Retrieved 2025-04-10.
- ^ a b c d "LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER'S MANUAL" (PDF). Ludlum Measurements. 2014. Retrieved 2025-04-10.
- ^ a b "Model 25 Series". ludlums.com. Retrieved 2025-04-10.
- ^ a b "Model 25-IS Series". ludlums.com. Retrieved 2025-04-10.
- ^ "FNIRSI® GC-01 Nuclear Radiation Detector". FNISRI. Archived from the original on 2025-04-05. Retrieved 2025-04-05.
- ^ "FNIRSI® GC-02 Geiger Counter Nuclear Radiation Detector". FNIRSI. Archived from the original on 2025-04-05. Retrieved 2025-04-05.
- ^ a b c d e f g h i j k Imported from Russian Wikipedia: Индивидуальные_дозиметры
- ^ a b c d e Imported from Ukrainian Wikipedia: Порівняння дозиметрів і радіометрів
- ^ Allimann.com
- ^ Дозиметр-радиометр АНРИ-01-02 "Сосна"
- ^ a b "Features - bGeigieZen". bgeigiezen.safecast.jp. 2022-02-24. Archived from the original on 2024-12-02. Retrieved 2024-12-02.
- ^ "Specifications". GitHub. Archived from the original on 2024-12-02. Retrieved 2024-12-02.
- ^ a b "bGeigieZen Assembled". bgeigiezen.safecast.jp. 2023-07-21. Archived from the original on 2024-12-02. Retrieved 2024-12-02.
- ^ Polimaster DKG-RM1203M or find a current model at Polimaster Ltd.
- ^ "DKG-21M: Personal Gamma Radiation Dosimeter". Ecotest. Retrieved 2025-05-05.
- ^ "PRD GUARDER: Personal radiation dosimeter DKG-24". Ecotest. Retrieved 2025-05-05.
- ^ "TERRA with Bluetooth channel: Dosimeter-Radiometer МКS-05". Ecotest. Retrieved 2025-05-05.
- ^ "MKS-UM: Multipurpose Dosimeter-Radiometer". Ecotest. Retrieved 2025-05-05.
- ^ a b c d e f g h i j k l m n "GQ Geiger Counter Selection Guide". GQ Electronics LLC. Retrieved 2022-10-06.
- ^ a b c "Radiacode 1ox series". Radiacode. Archived from the original on 2024-11-27. Retrieved 2024-11-27.
- ^ a b c Kolotukhin, Igor. "Quick Guide Manual". radiacode cyberspace. Radiacode. Archived from the original on 2024-11-27. Retrieved 2024-11-27 – via Coda.
- ^ "Detector of nuclear radiation and spectrometer Radiacode 102: SKU RC102". Radiacode. Archived from the original on 2024-11-27. Retrieved 2024-11-27.
- ^ "Detector of nuclear radiation and spectrometer Radiacode 103G: SKU RC103". Radiacode. Archived from the original on 2024-11-27. Retrieved 2024-11-27.
- ^ "Detector of nuclear radiation and spectrometer Radiacode 103G: SKU RC103G". Radiacode. Archived from the original on 2024-11-27. Retrieved 2024-11-27.
- ^ "Electronic Personal Dosimeter | RadTarge II D300 | X-Z LAB". X-Z LAB. Retrieved 2016-11-14.
- ^ "Electronic Personal Dosimeter | RadTarge II D700 | X-Z LAB". X-Z LAB. Retrieved 2016-11-14.
- ^ "Electronic Personal Dosimeter | RadTarge II D900 | X-Z LAB". X-Z LAB. Retrieved 2016-11-14.
- ^ "Rukovodstvo po ekspluatatsii radiometra RKS-20.03 "Pripyat"" Руководство по эксплуатации радиометра РКС-20.03 "Припять" [Operation manual for the RKS-20.03 "Pripyat" radiometer] (PDF).
{{cite web}}
: CS1 maint: url-status (link)
Literature
[edit]- "Intercomparison of personal dose equivalent measurements by active personal dosimeters" (PDF). International Atomic Energy Agency. Chicago. 2007.
- Bordy JM, Daures J, Clairand I, Denozière M, Donadille L, d'Errico F, Gouriou J, Itié C, Struelens L (2008). "Evaluation of the calibration procedure of active personal dosemeters for interventional radiology". Radiation Protection Dosimetry. 131 (1): 87–92. doi:10.1093/rpd/ncn225. PMID 18757898.
- "Comparison of Personal Dosimeters". Radiation Emergency Medical Management (REMM). United States Department of Health and Human Services. Retrieved October 10, 2022.